Practice portal › Thermal Properties of Matter › Junction and Interface Temperature

Three conductors of the same length are connected as follows: conductors 1 and 2, of thermal conductivities k₁ and k₂ and of equal cross-sectional area, are placed side by side between a face at 100 °C and a common face at θ °C; conductor 3, of thermal conductivity k₃ and of twice the cross-sectional area of conductor 1, runs from that common face at θ °C to a face at 0 °C. In the steady state the value of θ is ______ °C. (Given: k₁=60 J s⁻¹ m⁻¹ K⁻¹, k₂=120 J s⁻¹ m⁻¹ K⁻¹, k₃=135 J s⁻¹ m⁻¹ K⁻¹)

Asked in JEE Main 22nd Jan 1st Shift 2025 · Junction temperature

Figure: Junction temperature
Answer: 40

Step-by-step solution

Idea: conductors 1 and 2 span the same pair of faces, so they are in parallel and their conductances add; conductor 3 then carries the whole of that current onward, in series.

With each of 1 and 2 of area A and all three of length L, the parallel pair has conductance ((k₁+k₂)A)/L=(180A)/L.

Conductor 3 has area 2A, so its conductance is (k₃(2A))/L=(270A)/L.

Equating the heat currents: 180(100-θ)=270(θ-0).

18000=450θ, so θ=40 °C.

More Junction and Interface Temperature questionsAll Junction and Interface Temperature questions →

Reading this solution needs no sign-in. You only sign in to practise against the clock and keep your progress.

Practise this with a timer