Practice portal › Experimental Skills › Vernier Callipers

In a vernier calliper, (N+1) divisions of the vernier scale coincide with N divisions of the main scale. If 1 main scale division represents 0.1 mm, the vernier constant, in cm, is:

Asked in NEET 2024 · Least count

Answer: (2) 1/(100(N+1))

Step-by-step solution

Given: (N+1) VSD=N MSD and 1 MSD=0.1 mm=0.01 cm.

1 VSD=N/(N+1) MSD

Idea: the vernier constant is one main division minus one vernier division.

V.C.=MSD(1-N/(N+1))=(MSD)/(N+1)

V.C.=(0.01)/(N+1)=1/(100(N+1)) cm

Why the other options are wrong

More Vernier Callipers questionsAll Vernier Callipers questions →

Reading this solution needs no sign-in. You only sign in to practise against the clock and keep your progress.

Practise this with a timer