Practice portal › Alternating Current › AC Generator and Transformer

The primary of a transformer, when connected to a dc battery of 10 volt, draws a current of 1 mA. The number of turns of the primary and secondary are 50 and 100 respectively. The voltage in the secondary and the current in it are

Asked in NEET 2013 · Transformers

Answer: (3) Zero volt and therefore no current

Step-by-step solution

A transformer works by mutual induction: a changing flux in the core induces an emf in the

secondary.

A dc battery gives a steady current, so after the initial switch-on transient the flux in the

core is constant and (dφ)/(dt)=0.

With no changing flux there is no induced emf, so the secondary voltage is zero and no current

flows in it.

The turns ratio of 2 is irrelevant here: it scales an alternating voltage, and there is none.

Why the other options are wrong

More AC Generator and Transformer questionsAll AC Generator and Transformer questions →

Reading this solution needs no sign-in. You only sign in to practise against the clock and keep your progress.