Practice portal › Moving Charges and Magnetism › Moving Coil Galvanometer and its Conversion

The current sensitivity of a galvanometer can be increased by
(A) decreasing the number of turns
(B) increasing the magnetic field
(C) decreasing the area of the coil
(D) decreasing the torsional constant of the spring
Choose the most appropriate answer from the options given below.

Asked in JEE Main 28th July 1st Shift 2022 · Galvanometer sensitivity and figure of merit

Answer: (4) (B) and (D) only.

Step-by-step solution

Current sensitivity = θ/I = (NAB)/k.

It rises with larger N, A, B and smaller k.

So (B) and (D) are correct.

Why the other options are wrong

More Moving Coil Galvanometer and its Conversion questionsAll Moving Coil Galvanometer and its Conversion questions →

Reading this solution needs no sign-in. You only sign in to practise against the clock and keep your progress.

Practise this with a timer