Practice portal › Experimental Skills › Refractive Index: Prism and Travelling Microscope

In an experiment for determination of refractive index of glass of a prism by i-δ, plot, it was found that a ray incident at angle 35°, suffers a deviation of 40° and that it emerges at angle 79°. In that case which of the following is closest to the maximum possible value of the refractive index?

Asked in JEE Main 2016 · Refractive index by prism and slab

Answer: (1) 1.5

Step-by-step solution

Step 1: the prism angle follows from the three readings.

A=i+e-δ=35°+79°-40°=74°.

Step 2: the observed deviation can never be less than the minimum deviation, so δₘᵢₙ≤40°. Since μ grows with δₘᵢₙ, the largest μ consistent with this reading comes from taking δₘᵢₙ=40°.

Step 3: μ=(sin ((A+δₘᵢₙ)/2))/(sin (A/2))=(sin 57°)/(sin 37°)=(0.8387)/(0.6018)=1.39.

Of the four printed values, 1.5 is the closest.

Why the other options are wrong

More Refractive Index: Prism and Travelling Microscope questionsAll Refractive Index: Prism and Travelling Microscope questions →

Reading this solution needs no sign-in. You only sign in to practise against the clock and keep your progress.

Practise this with a timer