Practice portal › Current Electricity › Electrical Energy and Power

In a building, there are 15 bulbs of 45 W, 15 bulbs of 100 W, 15 small fans of 10 W and 2 heaters of 1 kW. The voltage of electric main is 220 V. The minimum fuse capacity (rated value) of the building will be

Asked in JEE Main 7th Jan 2nd Shift 2020 · Rated bulbs and appliances

Answer: (1) 20 A

Step-by-step solution

Total load: 15×45+15×100+15×10+2×1000.

=675+1500+150+2000=4325 W.

Current drawn: I=(4325)/(220)≈19.7 A.

The fuse must carry at least this, so the smallest suitable rating is 20 A.